1、Remarkable Actual Results
2、Superior type (Alarm Output: Alarm / Trip 2 Steps, DC4~20mA Output, Indicator on the Panel)
3、Standard type (Alarm Output: 1 Step・Indicator on the Panel)
4、Compatible to all kinds of Pickups
5、Stand alone, Panel-implanted, Wall-mounted: Easy Installation
Outward Size
Displacement Monitoring
Model |
VM-90 MED Superior type |
VM-90 MED Standard type |
Frequency Range |
Medium
freq.type |
15~500Hz +0.5dB -3dB
15~500Hz ±0.5dB |
Low
freq.type |
5~300Hz +0.5dB -3dB
10~300Hz ±0.5dB |
|
Measuring Range(Full scale) |
0~20μmp-p、0~50μmp-p、0~100μmp-p、0~200μmp-p、0~500μmp-p
|
Alarm Step |
2 Steps |
1Step |
DC Output (for Recorder) |
4~20mA(for 0~300Ωload)
1~5V(Load over 100kΩ 250Ωconnected externally) |
― |
Alarm Action |
Activates at Alarm Set and higher level (Time Constant approx.3sec) |
Alarm setting Extent |
Continuously variable over 10~100% of Indicator Full Scale |
Alarm Contact |
1C Contact for each Alarm |
Alarm Contact Capacity |
250VAC 3.0A/24VDC 3.0A (for Resistive Load) |
Alarm Reset |
Automatic |
Ambient Temp.}39;Humidity |
0~50℃ 0~85%RH |
Power Supply |
50/60Hz |
Power Consumption |
Less than 15A |
Size}39;Mass |
W200×H105×D103 mm(excl. protrusion) 2kg |
*AC200/220V: option *Provide us Measurement Range before shipping
Velocity Monitoring
Model |
VM-90 MEV Superior type |
VM-90 MEV Standard type |
Frequency Range |
15~1000Hz +1dB -3dB
20~850Hz ±1dB |
Measurement Range
(Full Scale) |
0~1mm/s、0~2mm/s、0~5mm/s、0~10mm/s、0~20mm/s、0~50mm/s
|
Alarm Step |
2 Steps |
1Step |
DC Output (for Recorder) |
4~20mA(at 0~300Ωload)
1~5V(Load over 100kΩ 250Ωconnected externally) |
― |
Alarm Action |
Activates at Alarm Set and higher level (Time Constant approx.3sec) |
Alarm setting Extent |
Continuously variable over 10~100% of Indicator Full Scale |
Alarm Contact |
1C Contact for each Alarm |
Alarm Contact Capacity |
250VAC 3.0A/24VDC 3.0A (for Resistive Load) |
Alarm Reset |
Automatic |
Ambient Temp.}39;Humidity |
0~50℃ 0~85%RH |
Power Supply |
50/60Hz |